 Current Transducer LB 1000-SI/SP2
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
1000 A
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with 15 V ISN KN VC IC @ 1000 A max @ 1500 A max 1000 0 .. 1500 RM min RM max 0 0 25 5 A A mA VDC mA
Features
* Closed loop (compensated) current
transducer using the Hall effect
* Insulated plastic case recognized
according to UL 94-V0.
Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption
200 1 : 5000 15 21 + IS
Special features
* TA = + 10C .. + 50C * Shield between primary and
secondary.
Accuracy - Dynamic performance data
XG
Advantages
0.3 < 0.1 Typ Max 0.4 0.2 % % mA mA s A/s kHz
L
Overall accuracy @ IPN , TA = 25C Linearity error Offset current @ IP = 0, TA = 25C Thermal drift of IO + 10C .. + 50C Response time 1) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB)
IO IOT tr di/dt f
0.1
<1 > 50 DC .. 100
* * * * * * * *
Better zero crossing performance Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference * Current overload capability.
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 70C Mass Standards + 10 .. + 50 C - 25 .. + 85 C 40 700 g EN 50178 : 1997
Applications
* AC variable speed drives and servo
motor drives
* Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies
(UPS)
* Switched Mode Power Supplies
(SMPS)
* Power supplies for welding
applications.
Application domain
Note : 1) With a di/dt of 100 A/s
* Industrial.
050816/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 1/3
LEM Components
w w w.lem.com
Current Transducer LB 1000-SI/SP2 Isolation characteristics
Vd Vw R.m.s. voltage for AC isolation test, 50 Hz, 1 mn Impulse withstand voltage 1.2/50 s 6 17 Min 54.5 44.4 225 kV kV
dCp dCl CTI
Creepage distance Clearance distance Comparative Tracking Index (Group IIIa)
mm mm
Application examples
According to EN 50178 and CEI 61010-1 standards and following conditions :
* Over voltage category OV 3 * Pollution degree PD2 * Non-uniform field
EN 50178 dCp, dCI, Vw Single isolation Reinforced isolation Rated isolation voltage 5000 V 2500 V CEI 61010-1 Nominal voltage Cat IIIa 5000 V rms Cat IIIa 2500 V rms
Safety
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions.
Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected.
050816/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 2/3
LEM Components
w w w.lem.com
Dimensions LB 1000-SI/SP2 (in mm. 1 mm = 0.0394 inch)
Front view Left view
Secondary terminals
Terminal + : supply voltage + 15 V Terminal M : measure Terminal - : supply voltage - 15 V
Connection
Top view Mechanical characteristics
* General tolerance * Fastening
Recommended fastening torque * Primary through-hole * Connection of secondary 0.5 mm 4 slots 7 mm 4 M5 steel screws 4 Nm or 2.95 Lb. - Ft. 40 mm Faston 6.3 x 0.8 mm.
Remarks
* IS is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed
100C.
* Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
050816/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 3/3
LEM Components
w w w.lem.com


▲Up To Search▲   

 
Price & Availability of LB1000-SP2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X